18/30kv MV Power Cables Single Cores Cables Application 18/30kv MV Power Cables Single Cores Cables Construction Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 18/30kv MV Power Cables Single Cores Cables Application 18/30kv MV Power Cables Single Cores Cables Construction Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2.Â
18/30kv MV Power Cables Single Cores Cables Standards
IEC 60502 Part 2(3.6/6KV to 18/30KV)
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
Conductor Screen:Â The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation:Â XLPE
Nom. Cross Section Area
Insulation Thickness at Nominal Voltage
1.8/3KV
3.6/6KV
6/10KV
8.7/15KV
12/20KV
18/30KV
21/35KV
26/35KV
(Um=3.6KV)
(Um=7.2KV)
(Um=12KV)
(Um=17.5KV)
(Um=24KV)
(Um=36KV)
(Um=42KV)
(Um=42KV)
mm2
mm
mm
mm
mm
mm
mm
mm
mm
Â
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
10
2
2.5
-
-
-
-
-
-
16
2
2.5
3.4
-
-
-
-
-
25
2
2.5
3.4
4.5
-
-
-
-
35
2
2.5
3.4
4.5
5.5
-
-
-
50 - 185
2
2.5
3.4
4.5
5.5
8
9.3
10.5
240
2
2.6
3.4
4.5
5.5
8
9.3
10.5
300
2
2.8
3.4
4.5
5.5
8
9.3
10.5
400
2
3
3.4
4.5
5.5
8
9.3
10.5
500 - 1600Â
2.2-2.8Â
3.2
3.4
4.5
5.5
8
9.3
10.5
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable):Â The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):Â It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable
Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature: 20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U
Operating Voltage (Um)
Testing Voltage
 (rms)
18/30KV
36KV
63KV Â
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section AreaNom.
Insulation ThicknessCopper Tape Thickness
Copper Wire Screen Area*Â
Unarmoured Cables
Steel Wire Armoured Cables
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
WeightNom.
Bedding ThicknessArmour Wire Size
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
Weight
CU
AL
CU
AL
mm2
mm
mm
mm2
mm
mm
kg/km
mm
mm
mm
mm
kg/km
50
8
0.1
16
3.2
65
4340
3460
1.8
3.15
3.5
75
8950
8080
70
8
0.1
16
3.3
70
5220
3930
1.9
3.15
3.6
80
10150
8860
95
8
0.1
16
3.4
74
6240
4440
1.9
3.15
3.7
84
11390
9590
120
8
0.1
16
3.5
77
7180
4910
2
3.5
3.8
89
13200
10860
150
8
0.1
25
3.6
80
8220
5420
2.1
3.5
4
92
14520
11720
185
8
0.1
25
3.7
84
9540
6040
2.1
4
4.1
97
17020
13510
240
8
0.1
25
3.9
91
11720
7110
2.2
4
4.3
104
19810
15200
300
8
0.1
25
4
95
13790
8000
2.3
4.5
4.5
108
23310
17470
400
8
0.1
35
4.3
103
16820
9430
2.4
4.5
4.7
117
27010
19620
500
8
0.1
35
4.5
110
21550
12880
2.5
4.5
4.9
124
31130
22610
Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
AreaSteel Flat Wire Armoured Cables
Double Steel Tape Armoured Cables
Nom.
Bedding ThicknessArmour Wire Size
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
WeightNom.
Bedding ThicknessNo of Steel Tapes x Nom Tape ThicknessÂ
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
Weight
CU
AL
CU
AL
mm2
mm
mm
mm
mm
kg/km
mm
mm
mm
mm
kg/km
50
1.8
0.8
3.1
70.2
7490
6775
1.8
2x0.5
3.3
71.2
7300
6585
70
1.9
0.8
3.2
74
8590
7540
1.9
2x0.5
3.4
75
8390
7335
95
1.9
0.8
3.4
78.5
9990
8460
1.9
2x0.5
3.5
79.3
9740
8210
120
2
0.8
3.5
82.2
11250
9270
2
2x0.8
3.6
84.5
11845
9875
150
2.1
0.8
3.6
85.6
12510
10070
2.1
2x0.8
3.7
87.9
13120
10700
185
2.1
0.8
3.7
89.8
14155
11100
2.1
2x0.8
3.9
92.3
14850
11800
240
2.2
0.8
3.8
95.4
16740
12575
2.2
2x0.8
4
97.9
17480
13320
300
2.3
0.8
4
100.9
19310
14120
2.3
2x0.8
4.2
103.4
20080
14900
400
2.4
0.8
4.2
107.8
22840
16170
2.4
2x0.8
4.4
110.3
23660
17000
500
2.5
0.8
4.4
115.5
27200
18610
2.5
2x0.8
4.6
118
28080
19510
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area
D C Resistance
CU / ALA C Resistance
 CU / ALShort Circuit Rating of Conductor
CU / AL
(1 sec)Capaci tance
Charging Current
Short Circuit Rating of Copper Wire Screen Per Core(1 sec)
Short Circuit Rating of Copper Tape Screen Per Core(1 sec)
Reactance
Inductance
50
387/641
494/822
6.8/4.4
142
0.85
2.6
1
134
430
70
268/443
343/568
9.8/6.3
159
0.95
2.6
1
127
400
95
193/320
248/410
13.3/8.5
175
1.05
2.6
1.1
121
390
120
153/253
196/325
17.2/11.0
189
1.13
2.6
1.1
117
370
150
124/206
159/265
21.2/13.5
201
1.21
4.3
1.2
113
360
185
99.1/164
128/211
26.6/17.0
217
1.3
4.3
1.2
109
350
240
75.4/125
98/161
34.9/22.3
237
1.42
4.3
1.3
104
330
300
60.1/100
80/130
43.8/28.0
258
1.55
4.3
1.4
101
320
400
47.0/77.8
64/102
57.3/36.6
282
1.69
5.8
1.5
96
290
500
36.6/60.5
51/81
72.3/46.2
302
1.79
5.8
1.6
78
250
Â
18/30kv MV Power Cables Single Cores Cables Standards
IEC 60502 Part 2(3.6/6KV to 18/30KV)
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
Conductor Screen:Â The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation:Â XLPE
Nom. Cross Section Area
Insulation Thickness at Nominal Voltage
1.8/3KV
3.6/6KV
6/10KV
8.7/15KV
12/20KV
18/30KV
21/35KV
26/35KV
(Um=3.6KV)
(Um=7.2KV)
(Um=12KV)
(Um=17.5KV)
(Um=24KV)
(Um=36KV)
(Um=42KV)
(Um=42KV)
mm2
mm
mm
mm
mm
mm
mm
mm
mm
Â
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
XLPE
10
2
2.5
-
-
-
-
-
-
16
2
2.5
3.4
-
-
-
-
-
25
2
2.5
3.4
4.5
-
-
-
-
35
2
2.5
3.4
4.5
5.5
-
-
-
50 - 185
2
2.5
3.4
4.5
5.5
8
9.3
10.5
240
2
2.6
3.4
4.5
5.5
8
9.3
10.5
300
2
2.8
3.4
4.5
5.5
8
9.3
10.5
400
2
3
3.4
4.5
5.5
8
9.3
10.5
500 - 1600Â
2.2-2.8Â
3.2
3.4
4.5
5.5
8
9.3
10.5
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable):Â The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):Â It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable
Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature: 20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U
Operating Voltage (Um)
Testing Voltage
 (rms)
18/30KV
36KV
63KV Â
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section AreaNom.
Insulation ThicknessCopper Tape Thickness
Copper Wire Screen Area*Â
Unarmoured Cables
Steel Wire Armoured Cables
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
WeightNom.
Bedding ThicknessArmour Wire Size
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
Weight
CU
AL
CU
AL
mm2
mm
mm
mm2
mm
mm
kg/km
mm
mm
mm
mm
kg/km
50
8
0.1
16
3.2
65
4340
3460
1.8
3.15
3.5
75
8950
8080
70
8
0.1
16
3.3
70
5220
3930
1.9
3.15
3.6
80
10150
8860
95
8
0.1
16
3.4
74
6240
4440
1.9
3.15
3.7
84
11390
9590
120
8
0.1
16
3.5
77
7180
4910
2
3.5
3.8
89
13200
10860
150
8
0.1
25
3.6
80
8220
5420
2.1
3.5
4
92
14520
11720
185
8
0.1
25
3.7
84
9540
6040
2.1
4
4.1
97
17020
13510
240
8
0.1
25
3.9
91
11720
7110
2.2
4
4.3
104
19810
15200
300
8
0.1
25
4
95
13790
8000
2.3
4.5
4.5
108
23310
17470
400
8
0.1
35
4.3
103
16820
9430
2.4
4.5
4.7
117
27010
19620
500
8
0.1
35
4.5
110
21550
12880
2.5
4.5
4.9
124
31130
22610
Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
AreaSteel Flat Wire Armoured Cables
Double Steel Tape Armoured Cables
Nom.
Bedding ThicknessArmour Wire Size
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
WeightNom.
Bedding ThicknessNo of Steel Tapes x Nom Tape ThicknessÂ
Nom.
Sheath ThicknessApprox.
Overall DiameterApprox.
Weight
CU
AL
CU
AL
mm2
mm
mm
mm
mm
kg/km
mm
mm
mm
mm
kg/km
50
1.8
0.8
3.1
70.2
7490
6775
1.8
2x0.5
3.3
71.2
7300
6585
70
1.9
0.8
3.2
74
8590
7540
1.9
2x0.5
3.4
75
8390
7335
95
1.9
0.8
3.4
78.5
9990
8460
1.9
2x0.5
3.5
79.3
9740
8210
120
2
0.8
3.5
82.2
11250
9270
2
2x0.8
3.6
84.5
11845
9875
150
2.1
0.8
3.6
85.6
12510
10070
2.1
2x0.8
3.7
87.9
13120
10700
185
2.1
0.8
3.7
89.8
14155
11100
2.1
2x0.8
3.9
92.3
14850
11800
240
2.2
0.8
3.8
95.4
16740
12575
2.2
2x0.8
4
97.9
17480
13320
300
2.3
0.8
4
100.9
19310
14120
2.3
2x0.8
4.2
103.4
20080
14900
400
2.4
0.8
4.2
107.8
22840
16170
2.4
2x0.8
4.4
110.3
23660
17000
500
2.5
0.8
4.4
115.5
27200
18610
2.5
2x0.8
4.6
118
28080
19510
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area
D C Resistance
CU / ALA C Resistance
 CU / ALShort Circuit Rating of Conductor
CU / AL
(1 sec)Capaci tance
Charging Current
Short Circuit Rating of Copper Wire Screen Per Core(1 sec)
Short Circuit Rating of Copper Tape Screen Per Core(1 sec)
Reactance
Inductance
50
387/641
494/822
6.8/4.4
142
0.85
2.6
1
134
430
70
268/443
343/568
9.8/6.3
159
0.95
2.6
1
127
400
95
193/320
248/410
13.3/8.5
175
1.05
2.6
1.1
121
390
120
153/253
196/325
17.2/11.0
189
1.13
2.6
1.1
117
370
150
124/206
159/265
21.2/13.5
201
1.21
4.3
1.2
113
360
185
99.1/164
128/211
26.6/17.0
217
1.3
4.3
1.2
109
350
240
75.4/125
98/161
34.9/22.3
237
1.42
4.3
1.3
104
330
300
60.1/100
80/130
43.8/28.0
258
1.55
4.3
1.4
101
320
400
47.0/77.8
64/102
57.3/36.6
282
1.69
5.8
1.5
96
290
500
36.6/60.5
51/81
72.3/46.2
302
1.79
5.8
1.6
78
250
Â
18/30kv Mv Power Cables Single Cores Cables to IEC 60502
Model NO.: N2XSEY, N2XSEBY, N2XSEFGBY, N2XSERY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xseby, N2xsefgby, N2xsery
Brand: Jl
Rated Voltage: 18/30kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Model NO.: N2XSEY, N2XSEBY, N2XSEFGBY, N2XSERY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xseby, N2xsefgby, N2xsery
Brand: Jl
Rated Voltage: 18/30kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100