18/30kv Mv Power Cables Single Cores Cables to IEC 60502

Model NO.: N2XSEY, N2XSEBY, N2XSEFGBY, N2XSERY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xseby, N2xsefgby, N2xsery
Brand: Jl
Rated Voltage: 18/30kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Model NO.: N2XSEY, N2XSEBY, N2XSEFGBY, N2XSERY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xseby, N2xsefgby, N2xsery
Brand: Jl
Rated Voltage: 18/30kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100

18/30kv Mv Power Cables Single Cores Cables to IEC 60502

18/30kv MV Power Cables Single Cores Cables Standards

IEC 60502 Part 2(3.6/6KV to 18/30KV)

18/30kv MV Power Cables Single Cores Cables Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

18/30kv MV Power Cables Single Cores Cables Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation: XLPE

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5 - - - - - -
16 2 2.5 3.4 - - - - -
25 2 2.5 3.4 4.5 - - - -
35 2 2.5 3.4 4.5 5.5 - - -
50 - 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 - 1600  2.2-2.8  3.2 3.4 4.5 5.5 8 9.3 10.5
Insulaton Screen:  Double coper tape or tape wire with tape tape
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):  It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable

Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature:
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
 (rms)
18/30KV 36KV 63KV  
 
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section Area
Nom.
Insulation Thickness
Copper Tape Thickness Copper Wire Screen Area*  Unarmoured Cables Steel Wire Armoured Cables
Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
50 8 0.1 16 3.2 65 4340 3460 1.8 3.15 3.5 75 8950 8080
70 8 0.1 16 3.3 70 5220 3930 1.9 3.15 3.6 80 10150 8860
95 8 0.1 16 3.4 74 6240 4440 1.9 3.15 3.7 84 11390 9590
120 8 0.1 16 3.5 77 7180 4910 2 3.5 3.8 89 13200 10860
150 8 0.1 25 3.6 80 8220 5420 2.1 3.5 4 92 14520 11720
185 8 0.1 25 3.7 84 9540 6040 2.1 4 4.1 97 17020 13510
240 8 0.1 25 3.9 91 11720 7110 2.2 4 4.3 104 19810 15200
300 8 0.1 25 4 95 13790 8000 2.3 4.5 4.5 108 23310 17470
400 8 0.1 35 4.3 103 16820 9430 2.4 4.5 4.7 117 27010 19620
500 8 0.1 35 4.5 110 21550 12880 2.5 4.5 4.9 124 31130 22610

Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
Area
Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
No of Steel Tapes x Nom Tape Thickness  Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm mm kg/km mm mm mm mm kg/km
50 1.8 0.8 3.1 70.2 7490 6775 1.8 2x0.5 3.3 71.2 7300 6585
70 1.9 0.8 3.2 74 8590 7540 1.9 2x0.5 3.4 75 8390 7335
95 1.9 0.8 3.4 78.5 9990 8460 1.9 2x0.5 3.5 79.3 9740 8210
120 2 0.8 3.5 82.2 11250 9270 2 2x0.8 3.6 84.5 11845 9875
150 2.1 0.8 3.6 85.6 12510 10070 2.1 2x0.8 3.7 87.9 13120 10700
185 2.1 0.8 3.7 89.8 14155 11100 2.1 2x0.8 3.9 92.3 14850 11800
240 2.2 0.8 3.8 95.4 16740 12575 2.2 2x0.8 4 97.9 17480 13320
300 2.3 0.8 4 100.9 19310 14120 2.3 2x0.8 4.2 103.4 20080 14900
400 2.4 0.8 4.2 107.8 22840 16170 2.4 2x0.8 4.4 110.3 23660 17000
500 2.5 0.8 4.4 115.5 27200 18610 2.5 2x0.8 4.6 118 28080 19510

18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area D C Resistance
CU / AL
A C Resistance
 CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capaci tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core(1 sec) Short Circuit Rating of Copper Tape Screen Per Core(1 sec) Reactance Inductance
50 387/641 494/822 6.8/4.4 142 0.85 2.6 1 134 430
70 268/443 343/568 9.8/6.3 159 0.95 2.6 1 127 400
95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390
120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370
150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360
185 99.1/164 128/211 26.6/17.0 217 1.3 4.3 1.2 109 350
240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330
300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320
400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290
500 36.6/60.5 51/81 72.3/46.2 302 1.79 5.8 1.6 78 250


18/30kv Mv Power Cables Single Cores Cables to IEC 60502

18/30kv Mv Power Cables Single Cores Cables to IEC 60502


18/30kv Mv Power Cables Single Cores Cables to IEC 60502
18/30kv Mv Power Cables Single Cores Cables to IEC 60502


18/30kv Mv Power Cables Single Cores Cables to IEC 60502
 
18/30kv Mv Power Cables Single Cores Cables to IEC 60502

18/30kv MV Power Cables Single Cores Cables Standards

IEC 60502 Part 2(3.6/6KV to 18/30KV)

18/30kv MV Power Cables Single Cores Cables Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

18/30kv MV Power Cables Single Cores Cables Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation: XLPE

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5 - - - - - -
16 2 2.5 3.4 - - - - -
25 2 2.5 3.4 4.5 - - - -
35 2 2.5 3.4 4.5 5.5 - - -
50 - 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 - 1600  2.2-2.8  3.2 3.4 4.5 5.5 8 9.3 10.5
Insulaton Screen:  Double coper tape or tape wire with tape tape
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):  It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable

Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature:
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
 (rms)
18/30KV 36KV 63KV  
 
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section Area
Nom.
Insulation Thickness
Copper Tape Thickness Copper Wire Screen Area*  Unarmoured Cables Steel Wire Armoured Cables
Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
50 8 0.1 16 3.2 65 4340 3460 1.8 3.15 3.5 75 8950 8080
70 8 0.1 16 3.3 70 5220 3930 1.9 3.15 3.6 80 10150 8860
95 8 0.1 16 3.4 74 6240 4440 1.9 3.15 3.7 84 11390 9590
120 8 0.1 16 3.5 77 7180 4910 2 3.5 3.8 89 13200 10860
150 8 0.1 25 3.6 80 8220 5420 2.1 3.5 4 92 14520 11720
185 8 0.1 25 3.7 84 9540 6040 2.1 4 4.1 97 17020 13510
240 8 0.1 25 3.9 91 11720 7110 2.2 4 4.3 104 19810 15200
300 8 0.1 25 4 95 13790 8000 2.3 4.5 4.5 108 23310 17470
400 8 0.1 35 4.3 103 16820 9430 2.4 4.5 4.7 117 27010 19620
500 8 0.1 35 4.5 110 21550 12880 2.5 4.5 4.9 124 31130 22610

Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
Area
Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
No of Steel Tapes x Nom Tape Thickness  Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm mm kg/km mm mm mm mm kg/km
50 1.8 0.8 3.1 70.2 7490 6775 1.8 2x0.5 3.3 71.2 7300 6585
70 1.9 0.8 3.2 74 8590 7540 1.9 2x0.5 3.4 75 8390 7335
95 1.9 0.8 3.4 78.5 9990 8460 1.9 2x0.5 3.5 79.3 9740 8210
120 2 0.8 3.5 82.2 11250 9270 2 2x0.8 3.6 84.5 11845 9875
150 2.1 0.8 3.6 85.6 12510 10070 2.1 2x0.8 3.7 87.9 13120 10700
185 2.1 0.8 3.7 89.8 14155 11100 2.1 2x0.8 3.9 92.3 14850 11800
240 2.2 0.8 3.8 95.4 16740 12575 2.2 2x0.8 4 97.9 17480 13320
300 2.3 0.8 4 100.9 19310 14120 2.3 2x0.8 4.2 103.4 20080 14900
400 2.4 0.8 4.2 107.8 22840 16170 2.4 2x0.8 4.4 110.3 23660 17000
500 2.5 0.8 4.4 115.5 27200 18610 2.5 2x0.8 4.6 118 28080 19510

18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area D C Resistance
CU / AL
A C Resistance
 CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capaci tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core(1 sec) Short Circuit Rating of Copper Tape Screen Per Core(1 sec) Reactance Inductance
50 387/641 494/822 6.8/4.4 142 0.85 2.6 1 134 430
70 268/443 343/568 9.8/6.3 159 0.95 2.6 1 127 400
95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390
120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370
150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360
185 99.1/164 128/211 26.6/17.0 217 1.3 4.3 1.2 109 350
240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330
300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320
400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290
500 36.6/60.5 51/81 72.3/46.2 302 1.79 5.8 1.6 78 250