Relay operating term - cold switching detailed
Cold switching refers to the operation of a switch, such as a relay, where no significant user signal is present when the contacts are either open or closed. When a relay is carrying a user signal, current flows through the contacts at the moment they close. If the switch is open, this current is interrupted. In contrast, cold switching minimizes the stress on the relay by avoiding the flow of current during the switching process.
Compared to thermal switching, mechanical relays experience significantly reduced wear during cold switching, which helps extend their overall lifespan. However, solid-state relays typically have similar ratings for both hot and cold switching. This is because solid-state relays do not have physical contacts that can erode or arc, making them more suitable for frequent operations.
One key advantage of cold switching is that it allows for higher voltage and current ratings than thermal switching. This is because there is no arcing, metal migration, or radio frequency interference (RFI) at the contact points. In contrast, thermal switching can lead to arcing, especially in high-power applications, which can cause contact erosion over time. Inductive loads, such as motors or transformers, can exacerbate this issue by creating multiple arcs during disconnection, further reducing the relay's life.
However, in certain situations, thermal switching is necessary. For example, if precise timing is required between voltage application and measurement, thermal switching must be used. Additionally, in some designs, a high voltage rise rate—such as 1000 μV/μs—can interfere with the relay’s control system. This is particularly problematic when using a relay outside its cold switching rating, as rapid voltage changes can propagate through the signal path and disrupt the control circuit. To avoid such issues, it's recommended to manage the voltage rise time when using cold switching.
In digital systems, where even a brief interruption can affect the device's state, hot switching is often preferred. This ensures that the system remains stable and functional during the switching process.
For larger mechanical relays, thermal switching may also be necessary to ensure proper contact closure. Without current flowing through the contacts during the "wet" action, the connection might become unreliable.
Cold switching offers several benefits, including extended contact life—up to 10 to 100 times longer than with thermal switching. It also prevents break-before-make issues that could cause short circuits between devices. Additionally, it reduces transients when switching sensitive loads like DUTs (Devices Under Test) or instruments, as well as capacitive loads.
Mechanical relays benefit greatly from cold switching, as it reduces arcing, metal migration, and RFI, thereby maximizing their operational life.
Solid-state relays, on the other hand, offer near-infinite life when operated within their rated limits. They are not affected by the same contact degradation issues as mechanical relays. While frequent switching (above hundreds of Hz) can generate heat, faster switching results in less heat dissipation. Solid-state relays are ideal for applications requiring long-term reliability in hot switching environments. Unlike mechanical relays, they do not distinguish between hot and cold switching, making them versatile for various applications.