LV Nyry Electric Cable PVC Insulation Steel Wire Armoured

Model NO.: NYRY
4X70sq.Mm: 0.268 Ohm/Km
4X95sq.Mm: 0.193 Ohm/Km
4X16sq.Mm: 1.15 Ohm/Km
Trademark: JYTOP
Transport Package: Packed in Roll or Drums
Specification: As per popular international Standards
Origin: Zhengzhou, China
HS Code: 8544492100
Model NO.: NYRY
4X70sq.Mm: 0.268 Ohm/Km
4X95sq.Mm: 0.193 Ohm/Km
4X16sq.Mm: 1.15 Ohm/Km
Trademark: JYTOP
Transport Package: Packed in Roll or Drums
Specification: As per popular international Standards
Origin: Zhengzhou, China
HS Code: 8544492100
1KV NYFY ELECTRICAL CABLE Low voltage LV NYRY electric cable

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160 ° C
Nominal cross section of conductor >300mm2: 140 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid in high fall area, able to bear external mechanical force, and certain pulling force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
 
Cable size
 
Conductor type
Nominal thickness of PVC insulation (mm) Approx.
diameter
of steel
wire(mm)
Nominal thickness of PVC sheath(mm) Approx. cable overall diameter (mm) Max. D.C resistance @ 20 0 C  (Ω/km)
4x1.5mm 2 RE or RM 0.8 0.8 1.8 14.9 12.1
4x2.5mm 2 RE or RM 0.8 1.25 1.8 16.7 7.41
4x4mm 2 RE or RM 1.0 1.25 1.8 18.8 4.61
4x6mm 2 RE or RM 1.0 1.25 1.8 20.1 3.08
4x10mm 2 RM 1.0 1.6 1.8 23.9 1.83
4x16mm 2 RM 1.0 1.6 1.8 26.4 1.15
4x25mm 2 SM 1.2 1.6 1.9 27.8 0.727
4x35mm 2 SM 1.2 1.6 2.0 30.2 0.524
4x50mm 2 SM 1.4 1.6 2.1 33.7 0.387
4x70mm 2 SM 1.4 2.0 2.3 38.3 0.268
4x95mm 2 SM 1.6 2.0 2.4 43.2 0.193
4x120mm 2 SM 1.6 2.5 2.6 47.8 0.153
4x150mm 2 SM 1.8 2.5 2.7 51.8 0.124
4x185mm 2 SM 2.0 2.5 2.9 56.9 0.0991
4x240mm 2 SM 2.2 2.5 3.1 63.5 0.0754
4x300mm 2 SM 2.4 3.15 3.4 71.1 0.0601
4x400mm 2 SM 2.6 3.15 3.7 78.5 0.0470

LV Nyry Electric Cable PVC Insulation Steel Wire Armoured
  1KV NYFY ELECTRICAL CABLE Low voltage LV NYRY electric cable

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160 ° C
Nominal cross section of conductor >300mm2: 140 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid in high fall area, able to bear external mechanical force, and certain pulling force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
 
Cable size
 
Conductor type
Nominal thickness of PVC insulation (mm) Approx.
diameter
of steel
wire(mm)
Nominal thickness of PVC sheath(mm) Approx. cable overall diameter (mm) Max. D.C resistance @ 20 0 C  (Ω/km)
4x1.5mm 2 RE or RM 0.8 0.8 1.8 14.9 12.1
4x2.5mm 2 RE or RM 0.8 1.25 1.8 16.7 7.41
4x4mm 2 RE or RM 1.0 1.25 1.8 18.8 4.61
4x6mm 2 RE or RM 1.0 1.25 1.8 20.1 3.08
4x10mm 2 RM 1.0 1.6 1.8 23.9 1.83
4x16mm 2 RM 1.0 1.6 1.8 26.4 1.15
4x25mm 2 SM 1.2 1.6 1.9 27.8 0.727
4x35mm 2 SM 1.2 1.6 2.0 30.2 0.524
4x50mm 2 SM 1.4 1.6 2.1 33.7 0.387
4x70mm 2 SM 1.4 2.0 2.3 38.3 0.268
4x95mm 2 SM 1.6 2.0 2.4 43.2 0.193
4x120mm 2 SM 1.6 2.5 2.6 47.8 0.153
4x150mm 2 SM 1.8 2.5 2.7 51.8 0.124
4x185mm 2 SM 2.0 2.5 2.9 56.9 0.0991
4x240mm 2 SM 2.2 2.5 3.1 63.5 0.0754
4x300mm 2 SM 2.4 3.15 3.4 71.1 0.0601
4x400mm 2 SM 2.6 3.15 3.7 78.5 0.0470

LV Nyry Electric Cable PVC Insulation Steel Wire Armoured
 

Others Neodymium Magnet

Others Neodymium Magnet,Neodymium Magnet Hook,Magnetic Kitchen Knife Bar

Ningbo Wewinmagnet Co.,Ltd , http://www.wewinmagnet.com